B-70254EN/01 C.PARAMTER LIST
- 89 -
C.14 PARAMETERS FOR POWER TABLE SETTING
15280 Table interval when half of the discharge tubes are used
15281 Table interval when all discharge tubes are used
Data type: Word
Unit of data:
Range of data: 0 to 32767
Standard setting: Refer to the parameter data sheet delivered with the machine.
Set the increment in watts used for the setting in the output command.
15290 Power command 0 when half of the discharge tubes are used
15291 Power command 1 when half of the discharge tubes are used
15292 Power command 2 when half of the discharge tubes are used
15293 Power command 3 when half of the discharge tubes are used
15294 Power command 4 when half of the discharge tubes are used
15295 Power command 5 when half of the discharge tubes are used
15296 Power command 6 when half of the discharge tubes are used
15297 Power command 7 when half of the discharge tubes are used
15298 Power command 8 when half of the discharge tubes are used
Data type: Word
Unit of data: W
Range of data: 0 to 32767
Standard setting: Refer to the parameter data sheet delivered with the machine.
Sequentially set the output setting starting from 0 for each table
interval when half of the discharge tubes are used.