B-70254EN/01 C.PARAMTER LIST
- 81 -
15212 Maximum specifiable power when the duty ratio is not clamped
Data type: Word
Unit of data: W
Range of data: 0 to 32767
If PRM No. 15213 does not clamp the duty ratio to 50%, and a
specified power after power compensation and power feedback
processing exceeds the setting in this parameter, the power is clamped
to the setting.
If a value of 0 is set, the setting of parameter No. 15207 is set.
15213 Duty ratio clamp criterion
Data type: Word
Unit of data: W
Range of data: 0 to 7000
When a specified power multiplied by an override value exceeds the
value set in this parameter, the duty ratio is clamped to 50% (fixed
value), and the peak value is clamped to the value set in PRM No.
15210.0, the setting of parameter No. 15210 is set.
15214 Maximum setting for the CW-YAG laser frequency
Data type: Word
Unit of data: Hz
Range of data: 0 to 32767
For a CW-YAG laser oscillator, the frequency setting is clamped to
this value.
15215 Power input calibration coefficient
Data type: Word
Unit of data: W
Range of data: 102 (0.1×2
10
) to 10240 (10×2
10
)
(If 0 is specified, 1024 (10×2
10
) is assumed.)
Set the power input compensation factor.
15216 Power display filter time constant
Data type: Word
Unit of data: msec
Range of data: 0 to 32767
This is the filter time constant with which fluctuation in power
display is suppressed.