C.PARAMTER LIST B-70254EN/01
- 76 -
15136 Assist gas pressure
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set a desired assist gas pressure.
15137 Assist gas pressure set time for piercing
Data type: Word
Unit of data: 10msec
Range of data: 0 to 32767
Set a desired assist gas pressure set time for piercing.
15138 Assist gas pressure for piercing
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set a desired assist gas pressure for piercing.
15139 Assist gas stop time
Data type: Word
Unit of data: 10msec
Range of data: 0 to 32767
Set the wait time when the assist gas stops.