15257 Number of abnormal vibrations detected
Data type: Word
Unit of data:
Range of data: 0 to 32767
If the number of abnormal vibrations detected exceeds the value
specified in this parameter, an alarm is issued.
15258 Time constant of the filter used for laser gas pressure variation suppression
Data type: Word
Unit of data: msec
Range of data: 17to 32767 (If a value less than 16 is specified, the filter does not
function.)
15259 Exhaust time when RUN is ON
Data type: Word
Unit of data: sec
Range of data: 0 to 32767
Set a desired evacuation time when RUN is ON.
15260 Period when the exhaust value of the external pipe is open
Data type: Byte
Unit of data: sec
Range of data: 0 to 60 (When a time beyond 60 sec is specified, the time is clamped
to 60 sec.)