C.PARAMTER LIST B-70254EN/01
- 72 -
15095 Allowable variation in power control speed
Data type: Byte
Unit of data: mm/min (specified increment for B8F1-08 or earlier) or %
Range of data: 0 to 255
Standard setting: 4
Set the amount by which the power control speed is allowed to vary.
This parameter is valid when parameter No. 15450 is set to 0.
To set a value of 256 or greater, use parameter No. 15450.
Set this parameter according to the setting of bit 6 of parameter No.
15096 (SDB) as follows.
#7 #6 #5 #4 #3 #2 #1 #0
15096 EGM PCD PCF PCP
Data type: Bit
PCP
0: Does not control the output according to the feedrate in power
control.
1: Controls the output according to the feedrate in power control.
PCF
0: Does not control the frequency according to the feedrate in
power control.
1: Controls the frequency according to the feedrate in power
control.
PCD
0: Does not control the duty ratio according to the feedrate in
power control.
1: Controls the duty ratio according to the feedrate in power
control.
EGM
0: Cancels the power control mode in the edge machining or start-
up processing mode.
1: Stops power control only during return distance movement in the
edge machining or start-up processing mode.
In the edge machining or start-up processing mode, the E number for
specifying conditions for edge machining or start-up processing is
selected.
15097 Parameter for calculating the displacement of the output
(output at a speed of F = 0)
Data type: Word
Unit of data: v
Range of data: 0 to 7000