C.PARAMTER LIST B-70254EN/01
- 64 -
#7 #6 #5 #4 #3 #2 #1 #0
15011 OPV CSC LVE EDS
Data type: Bit
EDS
0: Uses the conventional conditions as the cutting conditions during
execution of edge machining or start-up processing for a return.
1: Uses the piercing operating conditions in edge machining for the
laser power, assist gas type, and assist gas pressure as cutting
conditions during execution of edge machining or start-up
processing for a return.
LVE
0: Performs assist gas switching according to the conventional
specifications at the start of edge machining and at the start of
cutting for the return distance after that.
1: Ignores the time setting when the gas type and pressure do not
change for assist gas switching at the start of edge machining
and at the start of cutting for the return distance after that.
CSC When the following four values, S, P, Q, and F, are concurrently
specified in the first G01, G02, or G03 block following G24 in the
start-up processing mode,
0: Executes conventional start-up processing without using the
specified S, P, Q, and F values.
1: Cancels operation of start-up processing and performs cutting
using the specified S, P, Q, and F values.
OPV
0: The external piping exhaust valve operates only once after
power-on.
1: The external piping exhaust valve always operates when RUN is
turned on.