B-70254EN/01 C.PARAMTER LIST
- 79 -
C.9 PARAMETERS FOR THE OSCILLATOR
15200 Power used for power compensation factor determination when half of the
discharge tubes are used
Data type: Word
Unit of data: W
Range of data: 0 to 32767
Set a power to find the power compensation factor when half of the
discharge tubes are used.
15201 Power used for power compensation factor determination when all
discharge tubes are used
Data type: Word
Unit of data: W
Range of data: 0 to 32767
Set a power to find the power compensation factor when all discharge
tubes are used.
15203 Power calibration limit
Data type: Word
Unit of data:
Range of data: 0 to 32767
If the power compensation factor exceeds this value, the low output
alarm signal (F220#6 MWRN) is output to notify the user of the time
to clean or replace the mirror.
15204 Power calibration coefficient
Data type: Word
Unit of data:
Range of data: 0 to 32767
This is to calibrate command power for real power. This parameter is
automatically set at power compensation after the oscillator start
signal (G222#6 RUN) is turned on.
15205 Power compensation time
Data type: Word
Unit of data: sec
Range of data: 0 to 32767
Set a power compensation time.