B-64014EN/03 OPERATION 1.OPERATING THE DATA SERVER FUNCTIONS
- 95 -
1.2.3 Preparations for File Operation and Editing
MAIN PROGRM
A selected file can be registered as a main program.
1 Select the EDIT mode or MEM mode.
2 By using cursor keys
, select a file to be registered as a
main program.
3 Press soft key [MAIN PROGRM].
A registered main program can be executed in memory operation or
edited.
NOTE
1 No file may be able to be selected, depending on
the status such as operation state or protection
state.
2 Only a text file can be selected as a main program.
3 For a file selected as a main program and a file
being used for memory operation, no comment is
displayed in detail display mode.
4 For a file selected as a main program, other file
operations are disabled.
5 For memory operation and editing, refer to the
USER'S MANUAL of the CNC.
M198 SET
A folder for M198-based subprogram calling can be specified.
1 Move to the folder containing a file to be called by M198-based
subprogram calling.
2 Press soft key [M198 SET].
NOTE
1 No file may be able to be selected, depending on
the status such as operation state or protection
state.
2 This setting is valid when the operating mode of the
Data Server is the storage mode.