B-64014EN/03 SETTING 5.SETTING THE MACHINE REMOTE DIAGNOSIS FUNCTIONS
- 77 -
5.3.2.2 When the start of machine remote diagnosis is rejected
INQU0 (G141#0)
INQU1 (G141#1)
INQU2 (G141#2)
DIAREQ (G141#5)
RMTCAN (F083#7)
<1>
<2>
<3>
<4>
The start of machine remote
diagnosis is rejected.
<5>
<1> Before the signal to request machine remote diagnosis
(DIAREQ) is set to "1", an inquiry destination for which to start
the remote diagnosis functions is selected using the inquiry
destination number signals (INQU0, INQU1, and INQU2). In
this example, "inquiry destination 3" is selected by setting
INQU0 = 1, INQU1 = 1, and INQU2 = 0.
<2> The signal to request machine remote diagnosis (DIAREQ) is set
to "1".
<3> When the machine remote diagnosis package rejects the request
to start diagnosis, the reject signal for machine remote diagnosis
acceptance (RMTCAN) is set to "1".
<4> When the reject signal for machine remote diagnosis acceptance
(RMTCAN) is set to "1", the signal to request machine remote
diagnosis (DIAREQ) is set to "0".
<5> When the signal to request machine remote diagnosis (DIAREQ)
is set to "0", the reject signal for machine remote diagnosis
acceptance (RMTCAN) is set to "0".