B-64014EN/03 SETTING 5.SETTING THE MACHINE REMOTE DIAGNOSIS FUNCTIONS
- 73 -
5.3 CONTROLLING THE MACHINE REMOTE DIAGNOSIS
FUNCTIONS FROM THE PMC
You can use signals from the PMC to control the start and forced
termination of the machine remote diagnosis functions and post the
status of the machine remote diagnosis functions and error numbers to
the PMC ladder.
5.3.1 Signals
No. #7 #6 #5 #4 #3 #2 #1 #0
G0141 DIAREQ DIASTP INQU2 INQU1 INQU0
DIAREQ <G0141#5>
[Name] Signal to request machine remote diagnosis
[Classification] Input signal
[Function] Requests the start of machine remote diagnosis.
[Operation] When this signal is set to "1", it requests the start of machine remote
diagnosis to the inquiry destination according to the signals indicating
the number of the inquiry destination (INQU0 to INQU2). When the
acceptance completion signal (RMTEND) or acceptance reject signal
(RMTCAN) is set to "1", this signal is set to "0".
DIASTP <G0141#4>
[Name] Signal to request machine remote diagnosis cancellation
[Classification] Input signal
[Function] Requests the forced termination of machine remote diagnosis.
[Operation] When this signal is set to "1", it requests forced termination to the
machine remote diagnosis accepting server. When the completion
signal for machine remote signal cancel acceptance (RMTCLS) is set
to "1", this signal is set to "0".
INQU2 <G0141#2>
INQU1 <G0141#1>
INQU0 <G0141#0>
[Name] Inquiry number select signals
[Classification] Input signal
[Function] Inquiry destination for which to start machine remote diagnosis
[Operation] Select an item from the table below as an inquiry destination for
which to start machine remote signal.
INQU2 INQU1 INQU0 Status
0 0 0 No selection
0 0 1 Inquiry destination 1
0 1 0 Inquiry destination 2
0 1 1 Inquiry destination 3