5.SETTING THE MACHINE REMOTE DIAGNOSIS FUNCTIONS SETTING B-64014EN/03
- 78 -
5.3.2.3 When machine remote diagnosis is forcibly terminated
DIASTP (G141#4)
RMTCLS (F082#3)
<1>
<2>
<3>
Machine remote diagnosis is
forcibly terminated.
<1> When the signal to request machine remote diagnosis
cancellation (DIASTP) is set to "1", the completion signal for
machine remote diagnosis cancel acceptance (RMTCLS) is set to
"1".
<2> When the completion signal for machine remote diagnosis cancel
acceptance (RMTCLS) is set to "1", the signal to request
machine remote diagnosis cancellation (DIASTP) is set to "0".
<3> When the signal to request machine remote diagnosis
cancellation (DIASTP) is set to "0", the completion signal for
machine remote diagnosis cancel acceptance (RMTCLS) is set to
"0" and the machine remote diagnosis functions are forcibly
terminated.