5.SETTING THE MACHINE REMOTE DIAGNOSIS FUNCTIONS SETTING B-64014EN/03
- 72 -
5.2 RELATED NC PARAMETERS
0024 Setting of communication with the PMC ladder development tool
[Data type] Byte
[Valid data range] 10: The high-speed interface (Ethernet) is used for PMC online
editing.
#7 #6 #5 #4 #3 #2 #1 #0
0904 DNS
[Data type] Bit
DNS The DNS function is:
0: Not used.
1: Used.
If this parameter has been modified, the power must be turned off then
back on for the modification to be become effective.
NOTE
To use the DNS function, set DNS IP ADDRESS 1
and DNS IP ADDRESS 2 on the COMMON
(DETAIL) screen.
#7 #6 #5 #4 #3 #2 #1 #0
8706 MRD
[Data type] Bit
MRD Type of communication device to be used by the machine remote
diagnosis functions:
0: The FAST Ethernet/FAST Data Server is not used.
1: The FAST Ethernet/FAST Data Server is used.
If this parameter has been modified, the power must be turned off then
back on for the modification to be become effective.