B-63943EN-2/01 6.MACRO EXECUTOR FUNCTION
- 131 -
NOTE
1 These commands are valid with 9.5" and 10.4"
LCD units only.
2 The commands specified in addresses X and Y
must be absolute commands at all times.
- P020 X_ Y_ R_
Registers a window frame mode.
R : Frame number (1 to 3)
X : Frame start point (X coordinate)
Y : Frame start point (Y coordinate)
The points X and Y represent coordinates in character display.
The size of a frame is fixed at 41 characters along the X-axis and at
14 lines along the Y-axis. If a specified frame of this size is larger
than the display area of the screen, the specification is ignored.
NOTE
1 These commands are valid with 9.5” and 10.4”
LCD units only.
2 The commands specified in addresses X and Y
must be absolute commands at all times.
- P021 R_
Selects a frame registered with P020.
This command does not display a frame but only selects a frame.
R : Selection number of a frame registered with P20
NOTE
1 These commands are valid with 9.5” and 10.4”
LCD units only.
2 When bit 3 (INCD) of compile parameter (No.
9167) is set to 1, the current coordinates for
incremental specification are preset.
- P022 R_
- P024 R_
Displays a frame registered with P020, as a selection window frame.
P022 clears the character display in a range.
R : Selection number of a frame registered with P20
NOTE
1 These commands are valid with 9.5” and 10.4”
LCD units only.
2 When bit 3 (INCD) of compile parameter (No.
9167) is set to 1, the current coordinates for
incremental specification are preset.