B-63943EN-2/01 6.MACRO EXECUTOR FUNCTION
- 239 -
PMC state signal read variables (#8715, #8725, #8735, and #8745)
To a PMC state signal read variable (#8715, #8725, #8735, and
#8745), the corresponding state signal (F130, F133, F136, and F139)
of the PMC axis control interface is written.
To a variable, one-byte signal interface data is assigned in decimal
format.
#7 #6 #5 #4 #3 #2 #1 #0
EBSYx EOTNx EOTPx EGENx EDENx EIALx ECKZx EINPx
x represents a group number from 1 to 4.
For details of each signal, refer to the “FANUC Series 30i-MODEL A
Connection Manual (Function)”.
6.12.2.3 Caution
CAUTION
1 An auxiliary function can be specified using
"G346". However, the auxiliary function strobe
signal "EMFg#p" cannot be controlled with a
conversational macro. Control the signal from the
PMC.
2 When this function is performing PMC axis control,
do not issue a control command from the PMC
side. To be specific, do not issue a PMC axis
control command, for example, by causing the
conversational macro to use the UO signal to
inform the PMC that PMC axis control is under way
and eventually allowing the PMC to reference this
signal. Be careful especially when a ladder or
macro program is updated to add or change a PMC
axis control sequence.
3 Once this function is used to perform PMC axis
control, before causing the PMC to perform PMC
axis control to the same axis, stop the macro
program (if it has been activated) and reset the
target axis on the PMC side (set the ECLRg#p to 1).