B-63943EN-2/01 6.MACRO EXECUTOR FUNCTION
- 241 -
4. First, the currently set values are displayed as follows:
CURRENT DATA :
USER FILE AREA SIZE = xx
NUMBER OF USER FILE = xx
DATA AREA SIZE (BYTE) = xx
SRAM FREE = xx
5. According to the displays, specify the size of the user file area
and the number of files that can be generated in the user file
area.
MODIFY DATA :
USER FILE AREA SIZE = ?
NUMBER OF USER FILE = ?
If you want to change the data, enter the desired value, and press
the
INPUT
key. If not, simply press the
INPUT
key. If you want
to cancel the setting, press the
RESET
key.
6. When setting ends, the following message is displayed.
• If the setting has not been changed:
"DATA NOT CHANGED" is displayed.
• If setting has been completed normally:
The new setting is displayed in the same manner as at step 4,
and "DATA SETTING END" is displayed.
• If an invalid value has been specified:
"SETTING ERROR" is displayed and followed by a
description of the cause of the error.
7. Pressing the
INPUT
key displays the macro compiler utility
screen again.
8. After user file area setup is completed normally, perform
formatting.
On the macro compiler utility screen, press the
3
and
INPUT
keys to select "3. USER FILE FORMAT."
9. When "USER FILE FORMAT OK? [Y/N]" is displayed, press
the
Y
key.
10. When formatting ends normally, "USER FILE FORMAT: END"
is displayed.
11. Pressing the
INPUT
key displays the macro compiler utility
screen again.
12. Press the
0
and
INPUT
keys to select "0. END."
13. When the IPL screen appears again, press the
0
and
INPUT
keys to select "0. END IPL."