B-63943EN-2/01 8.PARAMETERS
- 295 -
9056 Time-out period for waiting for transmission/reception
[Data type] Integer
[Unit of data] sec
[Valid data range] 0 to 180
Set a time-out period to be applied when the transmission/reception
function (G335 to G338) for reader/puncher interface control waits
for transmission/reception.
No time-out occurs when 0 is set.
#7 #6 #5 #4 #3 #2 #1 #0
9100 MSFT DLMT VKLN VGAR
[Data type] Bit
# 0 VGAR When the display command with background color (G250) is
specified:
0: Display with background color is disabled.
1: Display with background color is enabled.
# 4 VKLN In background color display, background display for the key input line
is:
0: Not provided.
1: Provided.
# 5 DLMT The area of display with background color is:
0: Not limited to the data area.
1: Limited to the data area.
NOTE
When this parameter is set to 1, the range of the
menu display area and soft key display area is
limited. A command specifying an area beyond this
range is ignored.
Menu display area:
Upper 2 lines for an indicator with 12 soft keys
Upper 1 line for an indicator with 7 soft keys
Soft key display area:
Lower 5 lines for an indicator with 12 soft keys
Upper 3 lines for an indicator with 7 soft keys
# 7 MSFT When no background color is specified, the conversational macro
screen:
0: Displays a soft key frame.
1: Does not display a soft key frame.