B-63943EN-2/01 6.MACRO EXECUTOR FUNCTION
- 231 -
Example
When the following settings are made, the 1st and
2nd axes are controlled:
EAX1 = 1
#8700 = 2
NOTE
1 If an integer out of a range between 0 and 20 is
specified in #8700, the control command is ignored.
2 If parameter (No. 8010) does not relate the group
and axis specified by #8602 and #8700, the control
command is ignored. When 0 is specified in
#8700, however, only the axis specified by
controlled axis selection signals EAX1 to
EAX32<G136> is controlled.
3 When the power is switched, #8700 = 0.
For details, refer to the connection manual of each model.