C.DIFFERENCES FROM THE Series 16i APPENDIX B-63943EN-2/01
- 336 -
C.6 MACRO EXECUTOR FUNCTIONS
Function
Series 16i Series 30i
Graphic resolution For an indicator with 7 soft keys
Bit 2 (HRGR) of compile parameter (No.
9003) = 0
Standard mode: 320×270 dots
Bit 2 (HRGR) of compile parameter (No.
9003) = 1
High resolution mode: 640×480 dots
640×480 dots as standard
Be sure to set bit 2 (HRGR) of compile
parameter (No. 9003) to 1.
Character display (G243)
Address X, Y
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.
Character display (G243)
Address D
The number of significant display digits is
8.
The number of significant display digits is
12.
(However, no more than 9 digits can be
specified using an immediate value.)
Character display(G243)
Address F
The maximum number of digits is 8.
The number of decimal places is 3.
The maximum number of digits is 12.
The number of decimal places is 6.
Sequence of modal
addresses processed with a
conversational macro
Unlike ordinary NC programs, the
conversational macro program processes
each address in the sequence in which
they were specified.
Example of operation
<1> F8.3;
G243 F5.1 D#100;
→ #100 is represented with F5.1.
<2> F8.3;
G243 D#100 F5.1;
→ #100 is represented with F8.3.
Like ordinary NC programs, the
conversational macro program processes
data other than character strings in block
units. Therefore, operations do not
change according to the specified
sequence.
If identical addresses are specified in one
block, the last address to specify is
assumed to be valid.
Linear drawing (G01)
Addresses X and Y
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.
Circular drawing (G02 and
G03)
Addresses X, Y, I, and J
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.
Graphic filling function
(G206)
Addresses X and Y
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.
Rectangular display (G204)
Addresses X, Y, I, and J
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.
Cursor (rectangular cursor)
display (G230)
Addresses X and Y
Absolute command only When bit 3 (INCD) of compile parameter
(No. 9167) is set to 1, switching between
the absolute command and incremental
command is enabled with G390/G391.