B-63943EN-2/01 8.PARAMETERS
- 283 -
8.1 COMPILE PARAMERTES
When the power is turned on, the compile parameters are initialized to
the values set in P-CODE variables. So, these parameters cannot be
modified, for example, from the MDI panel.
#7 #6 #5 #4 #3 #2 #1 #0
9000 M3MB M2MB M1MB M512 M256
9001 M4MB
[Data type] Bit
No.9000
# 2 M256
# 3 M512
# 4 M1MB
# 5 M2MB
# 6 M3MB
No.9001 # 2 M4MB P-CODE file size
M4MB M3MB M2MB M1MB M512 M256 P-CODE file size
0 0 0 0 0 1 256Kbyte
0 0 0 0 1 0 512Kbyte
0 0 0 1 0 0 1Mbyte
0 0 0 1 1 0 1.5Mbyte
0 0 1 0 0 0 2Mbyte
0 1 0 0 0 0 3Mbyte
1 0 0 0 0 0 4Mbyte
#7 #6 #5 #4 #3 #2 #1 #0
9002 EXT1 PWSR DAUX ACL2 ACL1 TCAL
[Data type] Bit
# 0 TCAL Subprogram call using a T code is:
0: Disabled.
1: Enabled.
# 1 ACL1 Subprogram call using a specific code (O9004/#146) is:
0: Disabled.
1: Enabled.
# 2 ACL2 Subprogram call using a specific code (O9005/#147) is:
0: Disabled.
1: Enabled.
# 5 DAUX When the power is turned on, the conversational macro function is:
0: Not executed.
1: Executed.