C.DIFFERENCES FROM THE Series 16i APPENDIX B-63943EN-2/01
- 340 -
C.8 PARAMETERS
Function
Series 16i Series 30i
Specification of UI/UO signals for an
execution macro/conversational macro
Compile parameter (No. 9006#0) Executor parameter (No. 9035#3)
Specification of the conversational
macro screen common to two-path
control
Compile parameter (No. 9007#0) Executor parameter (No. 9049)
The P-CODE number used with
each path is specified. (For each
path, the P-CODE number of an
execution macro can be specified
with No. 9048, and the P-CODE
number of an auxiliary macro can
be specified with No. 9050.)
Specification of P-CODE common
variables (#10000 and up)
Compile parameter (No. 9007#1) Executor parameter (No. 9051)
The area of variables used with
each path is specified.
Specification of extended P-CODE
common variables (#20000 and up)
Compile parameter (No. 9007#2) Executor parameter (No. 9052)
The area of variables used with
each path is specified.
Number of usable P-CODE variables
(#10000 and up)
When the compile parameter (No.
9037) is se to 1, 100 P-CODE
variables can be used.
When the executor parameter (No.
9053) is se to 1, one P-CODE
variable can be used.
Number of usable extended P-CODE
variables (#20000 and up)
When the compile parameter (No.
9044) is se to 1 :
- 12 extended P-CODE variables can
be used with integer type data.
- 30 extended P-CODE variables can
be used with floating-point.
When the executor parameter (No.
9054) is se to 1, one extended P-
CODE variable can be used with
all type data.
Setting the character display mode to
the brightness modulation mode
Compile parameter (No. 9008#7) Executor parameter (No. 9033#2)
Stopping reader/punch control based on
conversational macros upon NC reset
Compile parameter (No. 9009#4) Executor parameter (No. 9035#1)
PMC internal relay (R area) address of
the interlock mode signal for each axis
direction
Compile parameter (No. 9035) Executor parameter (No. 9069)
PMC internal relay (R area) bit position
of the interlock mode signal for each
axis direction
Compile parameter (No. 9036) Executor parameter (No. 9070)
Whether to include data in a cumulative
cutting distance value or not
Compile parameters (No. 9102#0 to
#2)
Executor parameters (No. 9026#0
to 9028#8)
Whether to enable or disable
subprogram calling based on an S code
None Compile parameter (No. 9105#0)
Whether to enable or disable
subprogram calling based on a second
auxiliary function code
None Compile parameter (No. 9105#1)
Integer unit of a cumulative cutting
distance value (#8554)
None Compile parameter (No. 9160#0)
Whether to increment #8501 by 100 or
not when a key input variable is used
with decimal point input
None Compile parameter (No. 9160#1)
Whether macro modal calling based on
a G code is performed for each
block/move command
None Compile parameter (No. 9163#1)