B-63943EN-2/01 6.MACRO EXECUTOR FUNCTION
- 161 -
6.1.4 Character String Registration Program Number Specification
(#8509)
Variable #8509 is the control variable for specifying the program in
which a character string is registered. See the explanation of address
P of G243 in Section 6.1.3.5, "Character display" for details.
6.1.5 Function Screen Control Function (#8510)
Variable #8510 can be used to determine which function screen is
currently displayed on the CNC screen.
In addition, variable #8510 can be used to switch the CNC screen to
the desired function screen by writing the corresponding value to the
variable.
For a small keyboard
Function screen
Value
of
#8510
POS
: POSITION screen 0
PROG
: PROGRAM screen 1
OFFSET
SETTING
: OFFSET/SETTING screen 2
SYSTEM
: SYSTEM screen (parameter, diagnosis, and so on) 3
MESSAGE
: ALARM/MESSAGE screen 4
CUSTOM
GRAPH
:
GRAPHIC/CONVERSATIONAL MACRO screen
(user screen)
5/6
(*)
* 5 for the graphic screen and 6 for user screens 1, 2, and 3
For a standard keyboard
Function screen
Value
of
#8510
POS
: POSITION screen 0
PROG
: PROGRAM screen 1
OFFSET
SETTING
: OFFSET/SETTING screen 2
SYSTEM
: SYSTEM screen (parameter, diagnosis, and so on) 3
MESSAGE
: ALARM/MESSAGE screen 4
GRAPH
: GRAPHIC screen 5