B-63404EN/03 OPERATION 1.DeviceNet FUNCTIONS
- 27 -
(1) To proceed to "3 VENDOR ID", "4 DEVICE TYPE" and "5
PRODUCT CODE", set the respective vendor ID, device type
and product code. These setting values are referenced to as
values specific to the connected slave. If the setting values do
not match the values specific to the connected slave, an error(s)
occurs. Note, however, that setting of these items is arbitrary.
(Communications will not be influenced if these setting values
are left at their "0000" settings. If these setting values are set to
"0000," the slaves will not be referenced.)
In a normal communications state with the connected slaves,
these values can be read and the respective items automatically
set by operating soft key [INIT].
(Refer to "1.2.3 Starting communications, Automatic setting of
slave parameters.")
(2) To proceed to "6 CONNECTION" set "0". The connection type
with the slave is Poll I/O Connection. Also set the connection
type on the slave device to Poll I/O Connection.
STATUS and CONDITION are displayed in this screen as diagnostics
information used for verifying the communications status.
Table 1.2.2 (b) describes this diagnostics information.