3. OPERATION
97
3) Condition Specify the conditions at which the . . . . . . .
tracing starts.
0 : When F1“Exec” key is pressed.
1 : When F1“Exec” key is pressed
and the trigger address signal rises.
2 : When F1“Exec” key is pressed
and the trigger address signal falls.
Notes
1 Condition 1 and 2 are effective when a trigger address is
specified.
4) Trigger Mode Sampled data for up to 10 seconds is . .
stored in the trace buffer.
A signal is stored in the buffer within 8 ms.
0 : AFTER
In this mode, signal status are
obtained in the period specified in
the SAMPLING TIME from the
time when the trigger conditions
are satisfied.
1 : ABOUT
In this mode, signal status are
obtained in the period specified in
the SAMPLING TIME with the
time at the middle when the trigger
conditions are satisfied.
2 : BEFORE
In this mode, signal status are
obtained in the period specified in
the SAMPLING TIME before the
trigger conditions are satisfied.
3 : ONLY
In this mode, the signal states are
obtained only when the trigger
conditions are satisfied.
Notes
2 Trigger mode 1 is effective when condition 1 is set.
Trigger mode 2 is effective when condition 2 is set.
5) Signal Address Specify up to 16 addresses at which the. . .
tracing is performed with PMC
addresses or symbol names.
Please select [OK] when setting is completed.
Please select [Cancel] or press the Esc key when you cancel
setting.
When [Init] is selected, parameter and trace data of Signal
Analysis Function is initialized.
(c) Setting of Signal Analysis Screen
Analysis setting dialog is displayed by pressing F10“SgnSet”.