B–62884EN/01
D. CONVERSION OF SEQUENCE PROGRAM
303
PC side
IBM PC/AT series MODE COM1: 4800,E,7,2
(PC DOS MODE MODE COM1: 9600,E,7,2
command) (for 9600 baud)
P–G side
IO NC,CN1,F1,F6
IO NC,CN1,F1,F6,BR10 (for 9600 baud)
Notes
1 The baud rate can be set to either 4800 or 9600. However,
note that when the PC baud rate is set to 9600, the
parameter BR10 must be added to the baud rate setting for
the P–G.
2 It is necessary to set these communications setting only for
doing this operation. After using this function, please
restore the communications settings as the section 2.1
(Chapter 1).
The CN number is not fixed. For the P–G or P–G Mark II, the CN
number can be any setting from CN1 to CN4. For the P–G Mate, the
CN number can be any setting from CN1 to CN3. However, note that
the CN number selected here must match the CN number of the IO
command. Use the cables specified in Appendix H.
Operation example
During uploading
Operation procedure Example of input and screen contents
<PC> <PG> Turn on power.
<PG> Enter IO command settings. IO NC, CN1, F1, F6 (, BR10)
<PC> IBM PC/AT Series : Enter MODE command settings. (See Section 2 of Communications Settings)
<PG> Store transmission data in P–G memory. Press the [F2] key to select menu item no.2.
<PC> Execute FLOADAT. Enters waiting state. FLOADAT FILENAME –u
<PC> “LOADER START” is displayed.
<PG> Set [F6] ON. Select no.4 on the menu.
<PC> Select any entry from 1 to 7 on the submenu.
Begins transmission. <PG> “EXECUTING” is displayed.
Completes transmission.
<PG> Returns to the menu. <PC> “Operation Complete” is displayed.
<PC> The message “Operation Complete” is displayed,
followed by the prompt “HIT ANY KEY”. Hit any key
to end operation.
“HIT ANY KEY” is displayed.
D.4.1.2
Communications
Settings