B–62884EN/01
3. OPERATION
111
Program on
PMC is running.
Program on
PMC is stopped.
Fig. 3.4.6.1 (j) Fig. 3.4.6.1 (k)
To change the ladder program execution status, select [2.
Diagnose] then use the “RUN/STOP the ladder” dialog box.
(d) Displaying the communication status
While communication with the PMC is being performed, the icon
shown in Fig. 3.4.6.1 (l) is visible. When communication with
the PMC has not been established, the icon indicated in Fig.
3.4.6.1 (m) is visible. (For details of icons, see (2), ”Displaying
the PMC status (icon)” in Section 3.4.1.2.)
Communication
is active.
Communication
is stopped.
Fig. 3.4.6.1 (l) Fig. 3.4.6.1 (m)
When changing the status of the communication being performed
with the PMC, use the [4. Communication] dialog box.
(6) Monitoring signals
(a) Opening ”Signal Status” window
Pull down the [2. Diagnose] menu, select [Signal Status] from the
menu, the ”Signal Status” window is displayed,
Signal Status
G00000 0 0000000:00
G00001 0 0000000:00
G00002 0 0000000:00
G00003 0 0000000:00
G00004 0 0000000:00
G00005 0 0000000:00
G00006 0 0000000:00
G00007 0 0000000:00
G00008 0 0 0 0 0000:00
G00009 0 0000000:00
Fig.3.4.6.1 (n)
and the functions of function keys change as following.