3. OPERATION
B–62884EN/01
40
Load from PMC program memory.
N : E–3160 Selected program is not same.
Load
Store
Disregard
Qiut
Quit On –Line function.
Disregard difference.
Store to PMC program memory.
Fig.3.4.1.2 (b)
Note
If the program does not match the program on the PMC the
dialog box shown above appears. This occurs, for example,
when a single program is modified by means of off–line
editing.
When the on–line monitor function is started for a program
that is loaded or stored, the dialog box does not appear.
Instead, the subprogram selection screen appears
immediately.
(e) Loading from the PMC
After communication with the PMC starts normally, the “SET
COMMUNICATION” dialog box closes automatically and the
“LOAD FROM PMC” dialog box is opened in its place.
Load Program
Transfer data type
F LADDER f ALL
0%
Exec Abort Cancel
100%
Fig.3.4.1.2 (c)