B–62884EN/01
3. OPERATION
49
(c) Selecting a subprogram (F7 [SpList])
A ladder program is monitoried and edited in units of subprograms.
This function is uesd to list existing subprograms and to select the
subporgram to be displayed.
Note
The on–line monitoring function of a step sequence program is not
supported.
The subprogram of a step sequence program is not selected.
1) Subprogram list display screen
Pressing F7 [SpList] causes a window to be displayed, as shown
below. Select the program to be displayed by pressing a cursor
key or the
Page
Up
,
Page
Down
keys then the
Enter
key.
Sub–program list
Ok Cancel
LEVEL 1
LEVEL2
P00001 (OPEN RIGHT DOOR) MOVE RIGHT DOOR TO LIMIT–SWIIT–R1
P00002 (OPEN LEFT DOOR) MOVE LEFT DOOR TO LIMIT–SWIIT–L1
S P00010 (GRIP WORK PIECE) PICK UP A WORK ON THE STAND
P00011 (PUT WORK PIECE) PUT DOWN A WORK
P00021 (CLOSE RIGHT DOOR) MOVE RIGHT DOOR TO LIMIT–SWTH–R2
P00022 (CLOSE LEFT DOOR) MOVE LEFT DOOR TO LIMIT–SWTH L2
Fig.3.4.3.1.1(b)
2) Display information
The following information appears on the subprogram screen.
LEVEL 1
LEVEL2
P00001 (OPEN RIGHT DOOR) MOVE RIGHT DOOR TO LIMIT–SWIIT–R1
P00002 (OPEN LEFT DOOR) MOVE LEFT DOOR TO LIMIT–SWIIT–L1
S P00010 (GRIP WORK PIECE) PICK UP A WORK ON THE STAND
Step Sequence
(S mark)
Ladder (No mark)
Sub–program No. Symbol Coil comment
Fig.3.4.3.1.1(c)