B–62884EN/01
3. OPERATION
73
Setting of Ladder Debug Parameter Dialog
Ladder Debug Mode : Break Control
Break–Mode : Scan
Count : 1 to 65535
* Setting other than the above–mentioned item are invalid.
When F1“Exec” is pressed, the execution of stop operation
(scan) is started.
While executing stop operation (scan), stop operation (scan)
is stopped by pressing F1”Stop”
F1
Exec
F3
Dbgprm
F7
Splist
F8
Search
F9
Symbol
F10
Seting
(Stop)
SCAN COUNTER : 00000/65535 1995/12/20 13:20:59
Starting(/Stopping) the execution of stop operation (scan)
“Signal Status” window displays the status of signals on PMC in real
time. You can examine the signal status of any PMC address, and you can
also change the signal status on this window.
(1) Menu position
To activate “Signal Status” window, pull down [2. Diagnose] menu,
and select [signal Status] on the menu.
Ladder Monitor
Signal Status
PMC Parameter
PMC alarm status
PMC Status
RUN/STOP the program
Signal Trace
Signal Analysis
System Information
2. Diagnose
(2) Window view
When [SIGNAL STATUS] is selected, the window shown below
appears.
3.4.3.2
Signal Status Window