3. OPERATION
B–62884EN/01
66
F8
Search
F7
Splist
F9
Symbol
F10
Seting
[LEVEL1] NET 00001–00006
X0000.0 X0000.1 X0000.2 X0000.3 X0000.4 X0000.5 X0000.6 Y0000.1
G0500.3 R0900.0
X0010.7 Y0065.7
X0012.5 Y0014.2
SUB 1
END1
SUB 2
END2
COMM
ENT–
TRIGGER * MODE:ON : X0000.0 : 0 : 00000/65535 * 1995/12/20 13:20:59
F3
Dbgprm
(Stop)
F1
Exec
[Display of setting trigger]
” TRIGGER * MODE:ON : X0000.0: 0 :0000/12345 * 1995/12/20 13:20:59 ”
Stop time
COUNT:Trigger checking count
(default 1)
POINT:Trigger checking point (default 1)
0 – the top of the 1st level (Default 0)
1 – after END1 execution
2 – after END2 execution
3 – after END3 execution
ADR: Trigger setting address
ON:Rising edge detection
OFF:Falling edge detection
1) Stop operation to stop the execution of ladder when a trigger condi-
tion specified by signal becomes true.
F1
Exec
F3
Dbgprm
F7
Splist
F8
Search
F9
Symbol
F10
Seting
(Stop)
SCAN COUNTER : 00000/65535 1995/12/20 13:20:59
Stop time
[Display of setting scan]
” SCAN COUNT : 00000/00003 1995/12/20 13:20:59 ”
COUNT:Scan checking count
2) Stop operation to stop the execution of ladder after executing a scan.
Ladder Debug
1. File 2. Diagnose 3. I/O 4. Communication
Fig.3.4.3.1.4 (b) Screen of Stop Function of Break with Condition