3. OPERATION
B–62884EN/01
76
“PMC Parameter” sub-menu consists of the menu items for the windows
below.
1) Timer window
2) Counter window
3) Keep relay window
4) Data table control window
5) Data table window
To display the “Parameter” submenu, display the [2. Diagnose]
pull-down menu, then select [PMC Parameter] from the menu.
The submenu can be displayed by pressing the
or key with the
cursor positioned to [PMC Parameter].
Ladder Monitor
Signal Status
PMC Parameter
PMC alarm status
PMC Status
RUN/STOP the program
Signal Trace
Signal Analysis
System Information
Timer
Counter
Keep relay
Data table control
Data table
2. Diagnose
Warning
When changing a signal status or PMC parameter, extreme
care is necessary. If the function for modifying the signal
status or PMC parameter is applied incorrectly, the machine
may act unpredictably. Avoid using the function if personnel
are present near the machine.
Note
If you can not write PMC parameter, it might be protected.
For the detail, please refer PMC programing manual.
(1) Timer window
“Timer” window displays the contents of PMC Timer address. You
can examine the contents of PMC “Timer” address, and you can also
change the values for TMR instruction.
(a) Menu position
To active “Timer” window, pull down [2. Diagnose] menu, and
select [PMC Parameter] on the menu. Then sub-menu appears
which contains item [Timer] which activates “Timer” window.
3.4.3.3
PMC Parameter