4. ERROR MESSAGE LIST
271
Number Message Contents
N:E–3001 FLASH ROM WRITE ERROR
N:E–3003 FLASH ROM ERASE ERROR The F–ROM is faulty.
Replace the F–ROM.
Contact FANUC Service.
N:E–3006 FLASH ROM SIZE ERROR The size of the sequence program is greater than that of F–ROM.
Increase the size of F–ROM.
Try using the off–line CONDENSE function.
N:E–3007 FLASH ROM NOT EMG STOP The CNC is not in emergency stop status.
Set the CNC to emergency stop status.
N:E–3008 FLASH ROM PROGRAM DATA
ERROR
The PMC sequence program has failed.
Input the sequence program again.
N:E–3030 LADDER SIZE ERROR The sequence program is too large to be written to the PMC.
Check the size of the sequence program.
N:E–3031 PMC CONTROL TYPE BSI (RA1). When the PMC control module type is RA1, on–line editing cannot be
performed.
N:E–3036 PROGRAM SIZE ERROR
(OPTION).
The size of the sequence program exceeds the option–specified size.
Reduce the size of the sequence program.
N:E–3037 PMC TYPE UNMATCH. The PMC type is invalid.
Convert the machine model using the off–line function.
N:E–3038 NO OPTION (LADDER STEP). The ladder step number option does not exist.
N:E–3041 THE COMMUNICATION TO PMC IS
NOT READY.
Communication with the PMC has not been established.
Start communication with the PMC.
N:E–3042 AN ALARM OCCURS ON PMC. Processing cannot be continued because of a PMC alarm.
Clear the cause of the PMC alarm.
N:E–3045 LADDER SIZE OVER (PMC)
ERROR STATUS = nn
The ladder program being edited is too large to be written to the PMC.
Reduce the size of the ladder program.
N:E–3046 THE PROGRAM IS NOT
CORRESPONDING (PMC). STA-
TUS=NN
The program being edited does not match that of the PMC.
Load, store, or restore the program such that it matches the PMC pro-
gram.
N:E–3047 AN ALARM OCCURS ON PMC
ERROR STATUS = nn
Processing cannot be continued because a PMC alarm is issued.
Check whether the ladder data being edited is valid.
N:E–3048 LADDER DATA ERROR (PMC)
ERROR STATUS = nn
The program being edited does not match that of the PMC.
Load, store, or restore the program such that it matches the PMC pro-
gram.
N:E–3050 INPUT INVALID An invalid value has been entered.
Enter a valid value.
N:E–3051 OBJECT BUFFER OVER The sequence program is full.
Reduce the size of the ladder program.
N:E–3054 COM FUNCTION MISSING The usage of the COM (SUB9) functional instruction is invalid.
Check whether the usage of COM and COME (SUB29) is valid.
N:E–3055 JUMP FUNCTION MISSING The usage of the JMP (SUB10) functional instruction is invalid.
Check whether the usage of JMP and JMPE (SUB30) is valid.
4.13
N : ON–LINE
MONITOR
4.13.1
Error