3. OPERATION
B–62884EN/01
68
2) Step/Mode
Step
Mode
F Element
f Net
f Block
Element : Step Operation to execute one instruction
from current position. (Default)
Net : Step Operation to execute one net (one circuit)
from current position.
Block : Step operation to execute from current
position to specified contact or coil
instruction.
3) Step/Sub–Program
Step
V Sub–Program
(No–Check) : The step operations in Sub–Program
is not displayed.
X
(Check) : The step operations in Sub–Program
is displayed.
* When “b) Step/Mode” is “Element” or “Net”, it is possible
to set this item.
4) Break Control/Mode
Break Control
Mode
F Trigger f Scan
Trigger : Stop operation to stop the execution of ladder
when a trigger condition specified by signal
becomes true. (Optionally, a trigger counter can
be specified to stop after the trigger becomes true
specified times.)
Scan : Stop operation to stop the execution of ladder
after executing a scan. (Optionally, a scan
counter can be specified to stop after executing
specified times of scans.)