4. ERROR MESSAGE LIST
B–62884EN/01
278
Number Contents
N:E–3352 Address cannot be changed. Debug trigger is executing
[Cause] Trigger address cannot be changed because debug trigger is executing.
[Remedy] Please stop the execution of debug trigger.
N:E–3353 Count cannot be changed. Debug trigger is executing
[Cause] Trigger count cannot be changed because debug trigger is executing.
[Remedy] Please stop the execution of debug trigger.
N:E–3354 Count cannot be changed. Debug scan is executing
[Cause] Scan count cannot be changed because scan is executing.
[Remedy] Please stop the execution of scan.
N:E–3370 Signal analysis is unavailable
[Cause] Signal analysis not supports on PMC side.
[Remedy] It is necessary to exchange a system ROM of PMC.
N:E–3371 Signal analysis parameter error
[Cause] Signal analysis parameter is not corrected.
[Remedy] Please confirm the data of signal analysis parameter.
N:E–3372 Signal trace is executing. Cannot execute signal analysis
[Cause] Signal analysis cannot be executed because signal trace is executing on PMC side.
[Remedy] Please re–start signal analysis after signal trace was finished.
N:E–3373 Disable init for sampling
[Cause] Signal analysis cannot be initialized because signal analysis is executing on PMC side.
[Remedy] Please re–try parameter initialized after signal analyz was finished.
N:E–3374 Aborted signal analysis execution and initialize ?
[Cause] Signal analysis cannot be initialized because signal analysis is executing on PMC side by the keep
memory data of the old edition.