Ed. Date Design Description
Date Jan.07.’04 Design. Apprv.
page
-
44/64
FANUC Series 30i-MODEL A
Real time custom macro
A-79350EN
Title
Draw
No.
parameter No. 1601 for an NC statement is invalid. (However, the in-position signal
(INPx) for an NC statement is affected by the value of NCI.)
Manual absolute
The manual absolute signal (*ABSM) is invalid.
External deceleration
By setting bit 0 (EDC) of parameter No. 8005 to 1, the external deceleration function
can be used also for the axis being controlled by an RTM statement. Note, however,
that the external deceleration function is unusable for feed with a specified feedrate
(feed per revolution). For an external deceleration rate, the external deceleration
rate setting for rapid traverse (parameter No. 1427, No. 1441, and No. 1444) is valid,
regardless of the type of feed.
The external deceleration function for the axis being controlled by an RTM statement
is also valid for feed with a specified feedrate (feed per minute), regardless of the
settings of bit 4 (EDP) of parameter No. 1005 and bit 5 (EDM) of parameter No. 1005.
(The enabling of rapid traverse only is impossible.)
Mirror image
When enabling mirror image for the axis being controlled by an RTM statement, set
bit 0 (EMR) of parameter No. 8008 to 1, and set either bit 0 (MIRx) of parameter
No.0012 or mirror image signal MIx to '1'.
Programmable mirror image is not available.
PMC axis control axis selection signal (EAXn)
For the axis used with an RTM statement, the PMC axis control axis selection signal
(EAXn) need not be set to 1.
PMC axis control axis selection state signal (*EAXSL)
The axis being controlled by an RTM statement is also considered as a condition of
this signal. If an axis is being controlled by an RTM statement, the control axis
selection state signal (*EAXSL) is set to 1, so that the control axis selection signal
(EAXn) cannot be switched.
PMC axis simultaneous start mode
The simultaneous start mode cannot be used. The group used with an RTM
statement must not be set as a simultaneous start group with the simultaneous start
mode ON command.
PMC axis superposition
The axis used with an RTM statement cannot be used as a superposition axis.
Do not specify the group used with an RTM statement as a superposition axis.
Ensure that the axis control superposition command signal (EASIPx) for the axis
specified by an RTM statement is set to 0 at all times.