Address without the decimal point
In general, an NC address without the decimal point is subject to calculator-type
decimal point input when bit 0 (DPI) of parameter No. 3401 or bit 0 (AXDx) of
parameter No. 3455 is set to 1. In other cases, an NC address without the decimal
point is regarded as a least input increment.
Indirect axis address specification
When indirect axis address specification is used, use a direct reference argument.
No indirect reference may be used.
Example)
AX[1] Correct
AX[#RV[0]] Incorrect
Diameter specification/radius specification
For an axis to be controlled with an RTM statement, select radius specification. (Set
bit 3 (DIA) of parameter No. 1006 to 0.)
P/S alarm 224
If bit 0 (ZRN) of parameter No. 1005 is set to 0, and an axis control command is
specified in an NC statement before a reference position return operation is not
performed even once after power-up, P/S alarm 224 (ZERO RETURN NOT
FINISHED.) is issued. In axis control using an RTM statement, the alarm is not
issued even when bit 0 (ZRN) of parameter No. 1005 is set to 0, unless bit 6 (EZR) of
parameter No. 8006 is set to 1.
Axis removal
Even when axes are removed, interlock is not applied to the axis being controlled by
an RTM statement.
Stroke limit check before movement
No stroke limit check before movement is made with a block in an RTM statement.