15
50
FANUC Series 16i-TB
2 CPU 3-path control function
Specifications
-78884E
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
01 Aug.01.’02 Newly registered
SHEET
(5) Signals
(a) Synchronous control axis selection signals SYNC1-8 <G0138#0-7(G1138/G2138)>
7 6 5 4 3 2 1 0
G0138 SYNC8 SYNC7 SYNC6 SYNC5 SYNC4 SYNC3 SYNC2 SYNC1
G1138 SYNC8 SYNC7 SYNC6 SYNC5 SYNC4 SYNC3 SYNC2 SYNC1
G2138 SYNC8 SYNC7 SYNC6 SYNC5 SYNC4 SYNC3 SYNC2 SYNC1
[Classification] Input signal
[Function] These signals perform synchronous control.
[Operation] When one of these signals becomes "1", the control unit:
Begins synchronous control in such a way that the corresponding
axis becomes a slave axis.
The axis with which the slave axis is synchronized is determined by
parameter No.8180.
(b) Parking signals PK1-8 <G0122#0-7/G1122#0-7/G2122#0-7>
7 6 5 4 3 2 1 0
G0122 PK8 PK7 PK6 PK5 PK4 PK3 PK2 PK1
G1122 PK8 PK7 PK6 PK5 PK4 PK3 PK2 PK1
G2122 PK8 PK7 PK6 PK5 PK4 PK3 PK2 PK1
[Classification] Input signal
[Function] These signals place each axis in a parking state.
[Operation] When one of these signals becomes "1", the control unit:
Places the corresponding axis in a parking state.
If the corresponding axis is under synchronous control, it enters a
parking state immediately regardless of whether the axis is moving. If a
parking signal is set to "1" without specifying synchronous control, it is
ignored.