18
50
FANUC Series 16i-TB
2 CPU 3-path control function
Specifications
-78884E
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
01 Aug.01.’02 Newly registered
SHEET
(6) Parameter
7 6 5 4 3 2 1 0
8160 NRS SPE
[Data type] Bit
SPE The synchronization deviation is:
0: The difference between the positioning deviation of the master axis and
that of the slave axis.
1: The difference between the positioning deviation of the master axis and
that of the slave axis plus the acceleration/deceleration delay.
NRS When the system is reset, synchronous, composite or superimposed control is:
0: Released.
1: Not released.
7 6 5 4 3 2 1 0
8161 CZM NMR
[Data type] Bit
NMR When an axis subject to composite control is placed in servo-off state.
0: Composite control is stopped.
1: Composite control is not stopped, provided bit0(FUP) of parameter
No.1819 is set to 1 to disable follow-up for the axis.
CZM When two Cs contour axes are subject to mixed control, the function for
mixing zero point return commands for Cs contour axes is:
0: Not used
1: Used