30
50
FANUC Series 16i-TB
2 CPU 3-path control function
Specifications
-78884E
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
01 Aug.01.’02 Newly registered
SHEET
(6) Signals
(a) Spindle command select signals
7 6 5 4 3 2 1 0
G0063 SLSPB
#1
SLSPA
#1
G1063 SLSPB
#2
SLSPA
#2
G2063 SLSPB
#3
SLSPA
#3
[Classification] Input signal
[Function] Selects which spindle receives spindle command of which path.
[Operation]
Spindle command
on path 1
Spindle command
on path 2
Spindle command
on path 3
Spindles
on path 1
SLSPA
#1
=1
SLSPB
#1
=0
SLSPA
#1
=0
SLSPB
#1
=1
SLSPA
#1
=1
SLSPB
#1
=1
Spindles
on path 2
SLSPA
#2
=1
SLSPB
#2
=0
SLSPA
#2
=0
SLSPB
#2
=1
SLSPA
#2
=1
SLSPB
#2
=1
Spindles
on path 3
SLSPA
#3
=1
SLSPB
#3
=0
SLSPA
#3
=0
SLSPB
#3
=1
SLSPA
#3
=1
SLSPB
#3
=1
To control spindles on path 2 by command on path 3, set SLSPA,B
#2
to (1,1). At this time, if SLSPA,B
#1
or SLSPA,B
#3
are set (1,1), the
spindle on path 1 or path 3 also rotates by command of path 3.
Notice
If both of SLSPA and SLSPB are “0”, spindle command output “0”.