22
50
FANUC Series 16i-TB
2 CPU 3-path control function
Specifications
-78884E
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
01 Aug.01.’02 Newly registered
SHEET
8181
Synchronization error limit of each axis (Synchronous or composite
control)
[Data type] Two-word axis
[Unit of data] Unit of detection
[Valid data range] 0 to 32767
When the synchronization deviation detected (SERx of bit #1 parameter
No.8162 is set to 1), this parameter specifies the limit of the difference
between the positioning deviation of the slave axis and that of the master
axis. Set this parameter to the slave axis.
8182
Display of the synchronization error of an axis (synchronous or
composite control)
[Data type] Two-word axis
[Unit of data] Unit of detection
[Valid data range] 0 to more
When the synchronization deviation detected (SERx of bit #1 parameter
No.8162 is set to 1), this parameter specifies the difference between the
positioning deviation of the slave axis and that of the master axis. (The value
is used for diagnosis.) The deviation is display on the slave side.
The parameter is only of display. It should not be set.
The difference between the positioning deviation is:
(Positioning deviation of the master axis)
± (Position deviation of the slave axis)
Plus for a mirror-image synchronization command.
Minus for a simple synchronization command.
8183 Axis under composite control corresponding to an axis of another path
[Data type] Byte axis
[Valid data range] 0,11,12,13,... to [number of path] ✕10+[maximum number of control axes]
(11,12,13,...,21,22,...,31,32,...)
This parameter specifies an axis to be placed under composite control with
each axis of another path. When zero is specified, control of the axis is not
replaced under composite control. An identical number can be specified in
two or more axes, but composite control be exercised for all of item at a time.
NOTE
Set to the axis on which the composite control axis selection
signal is turned on or off.