35
50
FANUC Series 16i-TB
2 CPU 3-path control function
Specifications
-78884E
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
01 Aug.01.’02 Newly registered
SHEET
(7) Parameter
7 6 5 4 3 2 1 0
3702 ECS ESS EAS ESI EMS
[Data type] Bit
EMS The Multi-spindle control function is:
0: Used.
1: Not used.
ESI The Spindle positioning function is:
0: Used.
1: Not used.
EAS The Spindle analog output function is:
0: Used on path 1, path 2, or path 3.
1: Not used.
ESS The Spindle serial output function is:
0: Used.
1: Not used.
ECS The Spindle contouring function is:
0: Used
1: Not used.
7 6 5 4 3 2 1 0
3703 3SP 2SP
[Data type] Bit
In 3-path control, the setting of 2SP and 3SP is as follows:
2SP 3SP Spindle control
0 0 1-spindle control
1 0 2-spindle control
0 1 3-spindle control
1 1 Invalid
Notice
Parameter EMS,ESI,EAS,ESS, and ECS are valid in 2-path or 3-path system.
If the following options; Multi-spindle control, Spindle positioning , Spindle serial
output, Spindle serial output, and Cs contouring control; are attached, it is set
that whether to use those functions on each path.