4.PARAMETER SETTING START-UP B-65222EN/03
- 164 -
Fig. 4.1.1 (a) If the offset is set with a positive number
Fig. 4.1.1 (b) If the offset is set with a negative numbe
0.3 V (45°) or lower 2.2 V (315°) or higher
A
Phase Z
A
Phase Z
* The figures above show examples where AMR60 = 0. When
AMR60 = 1, "0.3 V (45°) or lower" should read "0.4 V (60°) or
lower", and "2.2 V (315°) or higher" should read "2.1 V (60°) or
higher".
5) Set the AMR offset parameter with A (or A - 360).
* The parameter setting range is:
-45 degrees to +45 degrees (when AMR60 = 0)
-60 degrees to +60 degrees (when AMR60 = 1)
When the value of A does not lie within the setting range, the
installation position of the linear encoder needs to be readjusted.
The voltage range of A allowing parameter setting, when
measured by analog voltage, is as follows:
0 V to 0.3 V and 2.2 V to 2.5 V (when AMR60 = 0)
0 V to 0.4 V and 2.1 V to 2.5 V (when AMR60 = 1)
6) Switch the power off and on again. Now parameter setting is
completed.
7) Observe the activating phase (AMR) again according to step 4)
above, and check that the activating phase changes continuously
in the phase Z rising portion.
Return the parameter set in step 3) above to 0.