B-65222EN/03 CONFIGURATIONS AND SELECTION 2.SELECTION METHODS
- 75 -
When the motor is driven with 200 V
Model name
Reference data for PSM selection (Maximum
output during acceleration/deceleration: kW)
300D/4
0m/s to 2.3m/s
P=V×1.4÷2.3
2.3m/s to 4m/s
1.4kW
600D/4
0m/s to 2.3m/s
P=V×2.7÷2.3
2.3m/s to 4m/s
2.7kW
900D/4
0m/s to 2.3m/s
P=V×4.1÷2.3
2.3m/s to 4m/s
4.1kW
1500A/4
0m/s to 2.1m/s
P=V×6.4÷2.1
2.1m/s to 4m/s
6.4kW
3000B/2
0m/s to 1m/s
P=V×8.6
1m/s to 2m/s
8.6kW
3000B/4
0m/s to 2.2m/s
P=V×12.1÷2.2
2.2m/s to 4m/s
12.1kW
6000B/2
0m/s to 1m/s
P=V×17.1
1m/s to 2m/s
17.1kW
6000B/4
0m/s to 2.2m/s
P=V×24.2÷2.2
2.2m/s to 4m/s
24.2kW
9000B/2
0m/s to 1m/s
P=V×28.3
1m/s to 2m/s
28.3kW
9000B/4
0m/s to 2.2m/s
P=V×36.3÷2.2
2.2m/s to 4m/s
36.3kW
15000C/2
0m/s to 1m/s
P=V×47.6
1m/s to 2m/s
47.6kW
15000C/3
0m/s to 1.5m/s
P=V×58.2÷1.5
1.5m/s to 3m/s
58.2kW
P: Maximum output (kW)
V: Maximum speed to be used (m/s)
When the motor is driven with 400 V
Model name
Reference data for PSM selection (Maximum
output during acceleration/deceleration: kW)
3000B/2
0m/s to 2m/s
P=V×12.1÷2
2m/s to 4m/s
12.1kW
6000B/2
0m/s to 2m/s
P=V×24.2÷2
2m/s to 4m/s
24.2kW
9000B/2
0m/s to 2m/s
P=V×36.3÷2
2m/s to 4m/s
36.3kW
15000C/2
0m/s to 1.6m/s
P=V×77.8÷1.6
1.6m/s to 4m/s
77.8kW
P: Maximum output (kW)
V: Maximum speed to be used (m/s)
NOTE
The values listed in the above table and values
obtained using the expressions in the above table
can be used only for power supply module selection.