B-65222EN/03 APPENDIX A.ORDERING DRAWING NUMBER
- 195 -
A ORDERING DRAWING NUMBER
NOTE
When placing a formal order, refer to "FANUC
LINEAR MOTOR series Ordering List (B-65221EN)".
For details including the specifications, dimensions,
and applicable amplifiers, see Part I,
"SPECIFICATIONS".
Model
name
Coil slider
NOTE 1
Magnet plate
NOTE 3
Cooling plate
NOTE 4
Piping component
Magnetic pole
sensor
NOTE 5
position detection
circuit
NOTE 5
300D/4 A06B-0421-B801 A06B-0423-K001
600D/4 A06B-0422-B801 A06B-0423-K002
900D/4 A06B-0423-B801
A06B-0423-B931
A06B-0423-B933
A06B-0423-K003
To be prepared by
the customer
A860-0331-T002
1500A/4 A06B-0410-B901
A06B-0410-B931
A06B-0410-B932
A06B-0410-B933
A06B-0410-B934
To be prepared by
the customer
A06B-0411-B901
NOTE 2
3000B/2
A06B-0411-B911
NOTE 2
3000B/4 A06B-0411-B811
A06B-0412-B901
NOTE 2
6000B/2
A06B-0412-B911
NOTE 2
6000B/4 A06B-0412-B811
A06B-0413-B901
NOTE 2
9000B/2
A06B-0413-B911
NOTE 2
9000B/4 A06B-0413-B811
A06B-0413-B931
A06B-0413-B932
A06B-0413-B933
A06B-0413-B934
15000C/2 A06B-0414-B901
15000C/3 A06B-0414-B811
A06B-0414-B921
A06B-0414-B922
A06B-0414-B923
A06B-0414-B924
Built-in
A06B-0413-K202
(Dedicated wrench)
A06B-0413-K203
(R1/4 conversion
joint)
A06B-0413-K204
(R1/8 conversion
joint)
A860-0331-T001
A860-0331-T001
(One-output type)
A860-0331-T002
NOTE 6
(Two-output type)
*1 For a FANUC nameplate, specify #0000 after each drawing number above. For a GE Fanuc nameplate, specify #7000
after each drawing number above.
*2 -B901 represents the power lead type (with a power lead directly extending from the coil slider), and -B911 represents
the terminal type. -B901 is a model for maintenance, so that it is not described in this manual. For a purpose other
than maintenance of an old model, specify -B911 whenever possible.
*3 Select a magnet plate suitable for the coil slider and axis length required.
*4 Option required for forced cooling (air cooling or water cooling) of 300D/4, 600D/4, and 900D/4. A spacer for the
magnetic pole sensor is delivered with this option.
*5 Required when an incremental linear encoder is used. Not required when an absolute linear encoder is used.
*6 To be specified only when a signal needs to be distributed to two systems from one linear encoder