4.FEED FUNCTION NC FUNCTION B-63942EN/02
- 154 -
4.21 EXTERNAL DECELERATION
The control axis is externally decelerated. The feedrate is decelerated
by the external deceleration signals from the machine. The
deceleration rate is set by the parameters.
The external deceleration signal are provided for each axis and
direction.
As five types of deceleration condition settings can be dynamically
selected by the signals.
External deceleration can be applied to rapid traverse rate, cutting
feedrate, and manual handle feedrate.
- Rapid traverse and cutting feed
Five types of deceleration conditions can be set by the parameters.
When deceleration conditions specified by multiple external signals
input during machining are conflicted, the condition with the lowest
external deceleration rate is applied.
External deceleration settings 2, 3, 4 and 5 can be switched between
enabled and disabled by the parameters.
- Manual handle feed
Five types of deceleration conditions can be set by the parameters. For
handle feed, the maximum feedrate is switched when the external
deceleration signal in the positive or negative direction for the handle
axis is set to 0. When multiple conditions are conflicted, the condition
with the lowest maximum feedrate is applied.
4.22 FEED STOP
During axis motion, the feed stop function checks a position deviation
amount at all times. When the amount exceeds the "feed stop position
deviation amount" set by the parameter, the function suspends pulse
distribution and acceleration/deceleration control during such a period
of time, and terminates the move command for the positioning control
circuit. Thus the function can minimize an overshoot that may occur
with a large servo motor in rapid traverse acceleration operation.
Speed
Time
Feed stop
Specified speed
ctual speed