B-63942EN/02 NC FUNCTION 8.TOOL FUNCTION / TOOL COMPENSATION FUNCTION
- 305 -
8.15.1 Tool Management Extension Function
- Customization of tool management data display
With the tool management data screen display customization
function, the display positions of screen elements (type number, tool
information, life counter, and so forth) on the tool management
screen can be changed and whether to display or hide such screen
elements can be chosen using the G10 format. This function
enables a customized tool management screen to be configured.
- Setting of spindle position/standby position display
In MG on the tool management data screen, a spindle position or
standby position is displayed as a number such as 11, 12, and 13.
With the spindle position/standby position display setting function,
three arbitrary characters can be displayed using the G10 format.
- Input of customize data with the decimal point
With the function for input of customize data with the decimal point,
the number of decimal places can be set using the G10 format for
each customize data item (customize data 1, ..., 40) to enable data
input with the decimal point.
- Protection of various tool information items with the KEY signal
When tool management data is in the edit state, various information
items can be modified. By setting the parameter, tool management
data can be protected with the KEY signal so that various
information items are not registered, modified, and deleted.
- Selection of a tool life count period
A tool life count period can be chosen between 1 sec and 8 msec on
a tool-by-tool basis.
- Individual data screen
All data for a specified tool can be extracted and displayed.
- Total life time display for tools of the same type
The remaining lives of tools with the same type numbers are totaled,
and totals are displayed in order by tool type number or by remaining
life. Also, tools with the same tool type numbers are displayed in a
list.
8.15.2 Tool Management Function Oversize Tools Support
Tool management function oversize tools support is added to the tool
management function.
The figure of an oversize tool can be defined freely, and the figure of
each oversize tool is registered. When an oversize tool is stored in a
cartridge, interference with tools stored in other pots is considered.
This function is usable with cartridges of chain type and matrix type.