8.TOOL FUNCTION / TOOL COMPENSATION FUNCTION NC FUNCTION B-63942EN/02
- 306 -
8.16 TOOL OFFSET VALUE COUNTER INPUT
T
A value displayed as a relative coordinate position can be set as an
offset value in tool compensation memory by using a soft key.
First, display the offset value screen. This screen also displays the
relative coordinate position. Next, select a reference tool, and
manually set it at the fixed point on the machine. Reset the relative
coordinates displayed on the screen to zero. Then, manually set the
tool to be measured at the same fixed point on the machine. At this
time, the relative coordinate position shows the difference between the
reference tool and the tool to be measured, and this value can be set as
the offset value.
8.17 TOOL LENGTH MEASUREMENT
M
The value displayed as a relative position can be set in the offset
memory as an offset value by a soft key.
Switch to the offset value display screen on the screen. Relative
positions are also displayed on this screen. Then select the reference
tool and set it at the fixed point on the machine by manual operation.
Reset the displayed relative position to zero. Set the tool for
measurement at the same fixed point on the machine by manual
operation. The relative position display at this point shows difference
between the reference tool and the tool measured and the relative
position display value is then set as offset amounts.
This difference is set
as offset amount.
Fixed point
Reference
tool