B-63942EN/02 NC FUNCTION 5.PROGRAM INPUT
- 205 -
5.28.4.8 Naming tool life states
The display name of a tool life state (0 to 4) can be set.
Format
G10 L77 P2 ;
N_ ;
P_ R_ ;
P_ R_ ;
N_ ;
P_ R_ ;
P_ R_ ;
G11 ;
N_: Tool life state (0 to 4)
P_: Character No. (1 to 12)
R_: Character code (ANK or shifted JIS)
- When a shifted JIS code is used, an area for
two characters is used.
- Specify 0 to clear data.
• A set display name can be checked on the tool management data
screen only.
• If no name is registered, a default such as "Remaining" and
"Unremaining" is displayed.
• A name consisting of up to 12 characters is displayed. For a
name shorter than 12 characters, register 0 in the empty area.
Those characters that are registered immediately before 0 are
displayed.
• To clear data, set 0 as a character code.
• No character code data check is made.
• The defaults are as follows:
0: Invalid
1: Remaining
2: Remaining
3: Unremaining
4: Broken