5.PROGRAM INPUT NC FUNCTION B-63942EN/02
- 204 -
5.28.4.6 Deleting cartridge management table data
Tool management data numbers can be deleted from the cartridge
management table.
Format
G10 L76 P3 ;
N cartridge-number P pot-number ;
N cartridge-number P pot-number ;
N cartridge-number P pot-number ;
N cartridge-number P pot-number ;
G11 ;
For a spindle position table and standby position table, only cartridge
number data is specified.
5.28.4.7 Naming customization data
The display name of customization data (0 to 40) can be set.
Format
G10 L77 P1 ;
N_ ;
P_ R_ ;
P_ R_ ;
;
N_ ;
P_ R_ ;
P_ R_ ;
G11 ;
N_: Customization data No. (0 to 40)
P_: Character No. (1 to 16)
R_: Character code (ANK or shifted JIS)
- When a shifted JIS code is used, an area for
two characters is used.
- Specify 0 to clear data.
• A set display name can be checked on the tool management data
screen only.
• When no name is registered, a name such as the default
"Customize 3" is displayed.
• A name consisting of up to 16 characters is displayed. For a
name shorter than 16 characters, register 0 in the empty area.
Those characters that are registered immediately before 0 are
displayed.
• To clear data, set 0 as a character code.
• No character code data check is made.