B-63942EN/02 NC FUNCTION 7.AUXILIARY FUNCTION / SPINDLE SPEED FUNCTION
- 267 -
The Fig. 7.4 (a) below shows the timing chart of these signals with the
new system. For comparison, Fig. 7.4 (b) shows the timing chart of
the conventional system.
Mx
Myy
Next block
Code signals
Strobe signal MF
PMC side operation
uxiliary function
completion si
nal MFIN
Fig. 7.4 (a) Timing chart of the high-speed system
Mxx
Myy
Next block
Code signals
Strobe signal MF
PMC side operation
Completion signal FIN
Fig. 7.4 (b) Timing chart of the usual system
NOTE
1 Which system, the usual system or high-speed
system, is to be used for transferring the strobe
signal and completion signal can be specified by
parameter setting.
2 The usual system used just one completion signal
(FIN), which is common to the M, S, T, and B
functions. In the high-speed system, a separate
completion signal is provided for each of the M, S,
T, and B functions.