5.PROGRAM INPUT NC FUNCTION B-63942EN/02
- 164 -
5.4 CONTROL-IN / CONTROL-OUT
Any information enclosed by the control-out and control-in codes is
regarded as a comment.
In a comment portion, however, the reset code (ISO code: % or EIA
code: ER) cannot be used. A portion ignored is referred to as a
"comment portion".
Name ISO code EIA code
Control-out ( 2-4-5 channel on
Control-in ) 2-4-7 channel on
5.5 OPTIONAL BLOCK SKIP
If a slash followed by a number (/n) is coded at the start of a block,
and optional block skip switch n on the machine operator's panel is
turned on, the information of the block where number /n
corresponding to switch number n is specified is ignored.
If optional block skip switch n is turned off, the information of the
block where /n is specified is not ignored. This means that the block
where /n is specified can be skipped according to the choice by the
operator.
As n, 1 can be used. The number 1 of /1 can be omitted.
Example)
/1 N12345 G00 X100. Z200. ;
5.6 OPTIONAL BLOCK SKIP EXTENSION
As n of /n for optional block skip, a number from 2 to 9 can be used.